37This would indicate that “larger is better” and that is the case for ideal capacitors if you would consider only the signal attenuation. A drawback of using very large capacitors is that reaching a steady-state DC bias condition may take very long. For example if you set the corner frequency at 1mHz then you would have to accept a startup time of several times 1000s...